Model Portfolio Table
Generator Model |
CCFJ8000J |
CCFJ9500J |
CCFJ11000J |
CCFJ13000J |
CCFJ14000J |
CCFJ16000J |
Engine Model |
10MV390 |
12MV390 |
14MV390 |
16MV390 |
18MV390 |
20MV390 |
Bore x Stroke (mm) |
390 x 550 |
|||||
Engine Type |
Four-Stroke, V type, direct Injection, Turbocharged, Intercooled |
|||||
Engine Rated Power (kW) |
8500 |
10200 |
11900 |
13600 |
15300 |
17000 |
Speed (rpm) |
50Hz@600 |
Electrical Performance
Voltage |
Voltage no-load regulation range |
% |
95~105 |
||
Voltage fluctuation rate |
% |
±1 |
|||
Steady state voltage regulating rate |
% |
±2.5 |
|||
Transient voltage regulating rate |
% |
±20~-15 |
|||
Stabilization time |
s |
1 |
|||
Alternator Excitation method |
|
Brushless AVR |
|||
Frequency |
Steady-state frequency (rev.) regulating rate |
% |
5 |
||
Frequency (rev.) fluctuation rate |
% |
±0.5 |
|||
Transient frequency regulating rate |
% |
±10 |
|||
Stabilization time |
s |
< 5 |
|||
Frequency regulating method |
|
Auto / Manual |
|||
Protection |
Over Speed |
115% Nr A, T, S |
Reverse Power |
-9.6% Pn A, T |
|
LO. Pressure |
0.25MPa A, 0.15MPa T, S |
Over Current |
130% In A, T |
||
Freshwater Temperature |
80℃ A, 85℃ T, S |
Over Voltage |
120% Vn A, T |
||
LO. Temperature |
90℃ A |
Overload |
110% In A |
Notes: All engine rating data is based on ISO 3046/1. Reference conditions: Ambient 45℃, Relative humidity 60%, Intercooler coolant inlet 32 ℃. If test ambient conditions are not the same as the fiducially ambient conditions. The power shall be revised according to ISO3046-1: 2002. Power: An overload of 10% is permitted for one hour every twelve hours of operation.
Characteristics:
Outline
Gensets Dimensions(approx.) |
||||
Model |
A |
B |
C |
Weight |
mm |
mm |
mm |
(kg) |
|
CCFJ8000J |
12100 |
3450 |
4900 |
137000 |
CCFJ9500J |
12950 |
3450 |
4900 |
150000 |
CCFJ11000J |
13790 |
3450 |
4900 |
178000 |
CCFJ13000J |
14630 |
3450 |
4900 |
191000 |
CCFJ14000J |
16470 |
3450 |
4900 |
209000 |
CCFJ16000J |
16310 |
3450 |
4900 |
223000 |
Remarks: Dimensions and weight are for reference only. For generator set model selection, please make communicate with relevant personnel. The delivery scope for each model engine shall be performed as per the corresponding technical files.