Manufactured by Cummins®, our commercial diesel generator sets seamlessly embody Cummins' universal design, production, and testing standards. This integration results in fully reliable and unified power generation systems that deliver optimal performance across a range of applications, including Standby power, Prime Power, and Continuous operation. These generator sets adhere to the ISO8528-2005 and GB/T2820-2009 standards for AC Generator Sets Driven by Reciprocating Internal Combustion Engine.
With certification in ISO9001 and ISO9002 for both generator set design and manufacturing, Cummins ensures complete quality assurance. We take full responsibility for the warranty of our generator sets, encompassing the engine, alternator, and control system.
Through our national specialized service network, we guarantee 24-hour post-sale service and the consistent availability of parts and accessories. With Cummins, you're not just purchasing a generator set; you're investing in an unwavering commitment to performance, reliability, and customer satisfaction.
Model Portfolio Table
Genset Model |
Standby power |
Prime power |
Engine |
Alternator |
Control system |
||
Kva |
Kw |
Kva |
Kw |
||||
C275D5B |
275 |
220 |
250 |
200 |
6LTAA9.5-G3 |
UCI274K |
PC1.2 |
Ratings definitions:
Emergency Standby Power (ESP):
Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. Emergency Standby Power (ESP) is in accordance with GB.T2820/ISO 8528. The effective oil limited power is in
accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514
Electrical Performance
Prime Power (PRP):
Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with GB.T2820/ISO 8528. A 10% overload capability is available
in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514.
Limited-Time Running Power (LTP):
Applicable for supplying power to a constant electrical load for limited hours. Limited-Time Running Power (LTP) is in accordance with GB.T2820/ISO 8528.
Base Load (Continuous) Power (COP):
Applicable for supplying power continuously to a constant electrical load for unlimited hours. Continuous Power (COP) is in accordance with GB.T2820/ISO 8528, ISO 3046,
AS 2789, DIN 6271 and BS 5514.
Cummins Power Generation C275D5B Diesel Generator Set specifications:
Voltage regulation (no load to full load) |
±1% |
Steady-state voltage variation |
±1% |
Frequency regulation (no load to full load) |
1.40% |
Steady-state frequency variation |
±0.25% |
EMC compatibility |
BS EN61000-6-4 /BS EN61000-6-2 |
Fuel consumption (L/hr) @ 100% load |
54 |
Total coolant capacity (engine and water tank), L |
55.5 |
Bottom oil tank capacity, L |
32.4 |
Outline
Model |
A |
B |
C |
Weight |
mm |
mm |
mm |
(kg) |
|
C275D5B |
2800 |
1100 |
1871 |
2738 |