We take pride in offering fully customized power plant solutions that cater to a diverse range of energy needs. Our solutions are designed to accommodate multiple fuel options, ensuring flexibility and adaptability to your specific requirements. Whether your preference lies in diesel, LPFO/HFO, biofuel, natural gas, tire pyrolysis oil, or other fuel sources, our power plant solutions can seamlessly integrate with your chosen energy source. This approach to customization allows us to align our power plant solutions with your unique operational and environmental considerations. By providing an array of fuel choices, we ensure that our solutions are not only versatile but also eco-friendly, meeting your sustainability goals while delivering reliable power output.
Model Portfolio Table
Generator Model |
MN8000F |
MN9500F |
MN11000F |
MN13000F |
MN14000F |
MN16000F |
Engine Model |
10MV390 |
12MV390 |
14MV390 |
16MV390 |
18MV390 |
20MV390 |
Bore x Stroke (mm) |
390 x 550 |
|||||
Engine Type |
Four-Stroke, V type, direct Injection, Turbocharged, Intercooled |
|||||
Engine Rated Power (kW) |
8500 |
10200 |
11900 |
13600 |
15300 |
17000 |
Speed (rpm) |
50Hz@600 |
8000 to 16000 kW Diesel Generator Sets Electrical Performance
Voltage |
Voltage no-load regulation range |
% |
95~105 |
||
Voltage fluctuation rate |
% |
±1 |
|||
Steady state voltage regulating rate |
% |
±2.5 |
|||
Transient voltage regulating rate |
% |
±20~-15 |
|||
Stabilization time |
s |
1 |
|||
Alternator Excitation method |
|
Brushless AVR |
|||
Frequency |
Steady-state frequency (rev.) regulating rate |
% |
5 |
||
Frequency (rev.) fluctuation rate |
% |
±0.5 |
|||
Transient frequency regulating rate |
% |
±10 |
|||
Stabilization time |
s |
< 5 |
|||
Frequency regulating method |
|
Auto / Manual |
|||
Protection |
Over Speed |
115% Nr A, T, S |
Reverse Power |
-9.6% Pn A, T |
|
LO. Pressure |
0.25MPa A, 0.15MPa T, S |
Over Current |
130% In A, T |
||
Freshwater Temperature |
80℃ A, 85℃ T, S |
Over Voltage |
120% Vn A, T |
||
LO. Temperature |
90℃ A |
Overload |
110% In A |
Notes: All engine rating data is based on ISO 3046/1.
Reference conditions: Ambient 45℃, Relative humidity 60%, Intercooler coolant inlet 32 ℃.
If test ambient conditions are not the same as the fiducially ambient conditions. The power shall be revised according to ISO3046-1: 2002. Power: An overload of 10% is permitted for one hour every twelve hours of operation.
Characteristics:
Meet with: ISO8528, ISO3046, GB/T13032.
Marine medium speed engine driven, unrestricted service configured, IMO Tier II D2 certified.
Brushless self-excited alternator with AVR, G3 electricity quality.
Application: Power plant set, Marine Auxiliary power.
As offer customized power plant solutions with multi-options fuels of diesel, LPFO/HFO, biofuel, natural gas, tire pyrolysis oil, etc.
Easy installation, high reliability, low noise, low operating cost, and environmentally friendly.
Outline
Gensets Dimensions(approx.) |
||||
Model |
A |
B |
C |
Weight |
mm |
mm |
mm |
(kg) |
|
MN8000F |
12100 |
3450 |
4900 |
137000 |
MN9500F |
12950 |
3450 |
4900 |
150000 |
MN11000F |
13790 |
3450 |
4900 |
178000 |
MN13000F |
14630 |
3450 |
4900 |
191000 |
MN14000F |
16470 |
3450 |
4900 |
209000 |
MN16000F |
16310 |
3450 |
4900 |
223000 |
Remarks: Dimensions and weight are for reference only. For generator set model selection, please make communicate with relevant personnel. The delivery scope for each model engine shall be performed as per the corresponding technical files.